Publication CIG-WD001A-EN-P - October 2003
7-2 1762 I/O on MicroLogix 1200 Controllers
+24
VDC
24
COM
IN 0 IN 2 IN 5 IN 7 IN 9
COM 1
IN 11 IN 13
COM 0
IN 1 IN 3 IN 4 IN 6 IN 8 IN 10 IN 12
-DCb
+DCb
+DCb
+DCa
+DCa
+DC
-DCa-DC
Input Group C om m on T e rm inal Inpu t Te rminal
Group 0 DC COM 0 I/0 through I /3
Group 1 DC COM 1 I/4 through I /13
Sinking Input Wiring
Terminal Groupings
The 24V dc sensor power source must not be used
to power output circuits. It should only be used
to power input devices (e.g. sensors, switches).
+24
VDC
24
COM
IN 0 IN 2 IN 5 IN 7 IN 9
COM 1
IN 11 IN 13
COM 0
IN 1 IN 3 IN 4 IN 6 IN 8 IN 10 IN 12
-DCb
-DC +DCa
-DCb
+DCb
+DC
-DCa
-DCa
24V dc Sensor Power
Input Group C om m on T e rm inal Inpu t Te rmina l
Group 0 DC COM 0 I/0 through I /3
Group 1 DC COM 1 I/4 through I /13
Sourcing Input Wiring
Terminal Groupings
The 24V dc sensor power source must not be used
to power output circuits. It should only be used
to power input devices (e.g. sensors, switches).
CR CR
CRCR
L2
L1
-DCa
+DCa L1a L1b
L2d
L2c L1d
L2a L2b
L2b
L1c
L2d
L2c
VAC
L1
VAC
NEUT
VAC
DC 0
VAC
DC 1
VAC
DC 2
OUT 3 VAC
DC 4
OUT 4 OUT 7 OUT 9
OUT 0 OUT 1 OUT 2 VAC
DC 3
OUT 5 OUT 6 OUT 8
Output Group Voltage Termin al Output Term in al
Group 0 VAC/VDC 0 O/0
Group 1 VAC/ VDC 1 O/1
Group 2 VAC/VDC 2 O/2 through O/3
Group 3 VAC/ VDC 3 O4 through O /5
Group 4 VAC/VDC 4 O/6 through O/9
Output Wiring
Terminal Groupings
1762-L24BWA