Publication 1761-UM006E-EN-P - August 2005
1761-NET-ENIW Web Server Capabilities 7-7
Figure 7.3 Example Write to First Integer on Second Data View Page
Floating-point Data
Floating-point data for the Data View pages is written to Node 203,
offset elements 0 through 11, as described in Table 7.3.
Floating-points in column 2 are right-justified with 7 significant digits
plus the decimal point. If an exponent is required, it is displayed as
‘e±xx’ with one significant digit to the left of the decimal point. The
valid range is ±1.175495e-38 to ±3.402823e+38.
Figure 7.4 Example Write to First Floating-Point on Second Data View Page