Programming
5-45
Diagnostics Group (continued)
F
q Sou
c
Parameter # 62
F
q Sou
c
Parameter Type Read
This parameter displays the frequency source currently
commanding the drive.
Units Text Displays ‘‘Remote Pot”
‘‘0-10 Volt”
‘‘4–20 mA”
‘‘MOP”
‘‘Adapter 1”
‘‘Adapter 2”
‘‘Adapter 3”
‘‘Adapter 4”
‘‘Adapter 5”
‘‘Adapter 6”
‘‘Preset 1”
‘‘Preset 2”
‘‘Preset 3”
‘‘Preset 4”
‘‘Preset 5’’
‘‘Preset 6”
‘‘Preset 7”
F
q Comm
nd
Parameter # 65 Factory Default 0.00 Hz
F
q Comm
nd
Parameter Type Read Only Minimum 0.00 Hz
This parameter displays the frequency that the drive is
commanded to output. This command may come from any
one of the frequency sources selected by [Freq Select 1],
[Freq Select 2] or [Preset Freq 1-7] as determined by
inputs to SW1, SW2 and SW3 at TB2.
Units 0.01 Hz Maximum 400.00 Hz
D
iv
Di
c
ion
Parameter # 69 Factory Default ‘‘Forward’’
D
iv
Di
c
ion
Parameter Type Read Only
This parameter displays the running direction of the drive. Units Text Displays ‘‘Forward”
‘‘Reverse”
o
o
od
Parameter # 43
o
o
od
Parameter Type Read Only
This parameter is used for internal diagnostic purposes.