Allen-Bradley 2-D Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 92
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
Installation and Wiring 2-3
Terminal Block Wiring
Terminal Block Wiring Detail Figure 2.2
Specifications
Terminal Block TB1 and TB2 Wiring Specifications Table 2.A
For single phase input applications, connect the AC input power to input terminals S (L2) and T (L3).
See Table 2.B for minimum recommended branch circuit protective devices.
Bulletin 160 Drives are UL Listed (see Appendix A for details) as motor overload protective devices
(IEC Class 10 overload). An external overload relay is not required
for single motor applications.
Model Screw Size Max./Min. Wire Size
mm
2
(AWG)
Max./Min. Torque
Nm (lb in)
4.0 kW (5 HP) M4 5.26 – 3.31 (10 – 12) 1.35 – 0.90 (12 – 8)
All Other Ratings M4 3.31 – 0.82 (12 – 18) 1.35 – 0.90 (12 – 8)
Required Branch
Circuit Disconnect
Branch Circuit
Protective Device
BR+
T/L3
S/L2
R/L1
BR–
DC+
W/T3
V/T2
U/T1
DC–
Ground Terminal/Protective Earth
Terminal Block TB1
Terminal Block TB2
Motor
Vista de pagina 14