Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012 115
Drive Comparisons Chapter 1
FlexPak 3000 AC Tachometer Interface Kit
See the FlexPak 3000 Drive AC Tachometer Interface Kit Installation
Instructions, publication FP3-IN003
, for more details.
Figure 89 - FlexPak 3000 Regulator Board Jumper Locations
Note: See Tab le 14 below for
jumper J11 and J14 settings.
Table 14 - Regulator Board Jumper Settings
Calculated DC Voltage from
Interface Board
Jumper Settings
(1)
(1) If you set the AC Tachometer Interface board parameters while performing the quick start procedure described in the FlexPak 3000
Drive User Manual, you will be prompted with these jumper settings.
J11 J14
Less than or equal to 16V 16 LO 62
17…31 Volts 31 / 125 LO 62
32…62 Volts 62 / 250 LO 62
63…125 Volts 31 / 125 HI 250
126…250 Volts 62 / 250 HI 250