Allen-Bradley 1770-M10 Especificaciones Pagina 126

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 194
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 125
126 Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012
Chapter 1 Drive Comparisons
Figure 96 - I/O Converter Board M_IN Terminal Block Designations
Table 31 - I/O Converter Board M_OUT Terminal Block Designations
No. Signal Description
1 Digital Input 1 Rated input voltage:115V AC ±10% 50 -
60Hz.
ON input voltage: 115V AC ±10%
OFF input voltage: 0 - 70V AC
ON input current: 4 - 5.5mA
2 Digital Input 2
3 Digital Input 3
4 Digital Input 4
5 Digital Input 5
6 Digital Input 6
7 Digital Input 7
8 Digital Input 8
Co
m
Digital Input Common
No. Signal Description
24V +24VDC Supply 24V DC ±10%, 40 mA power supply. max
load 120 mA.
Supply power can be provided by the +24V
DC supply on the Control board I/O (terminal
19 - see Figure 97
on 127) or an external
source (see Figure 98 on page 127).
1 Digital Output 1 Output type: Open collector, PNP type with
15kohm pull-down
Output current: 10 mA max.
Delay time hw OFF to ON: 5 ms (typ.)
Delay time hw ON to OFF: 50 ms (typ.)
2 Digital Output 2
3 Digital Output 3
4 Digital Output 4
5 Digital Output 5
6 Digital Output 6
7 Digital Output 7
8 Digital Output 8
0V 24V Common Common for the power supply.
If an internal supply is used, this terminal
must be wired to the digital input
common (terminal 16 or 35) on the
Control board I/O. See Figure 97
on 127.
If an external supply is used, this
terminal must be wired to the external
24V DC supply common and the digital
input common (terminal 16 or 35) on the
Control board I/O. See Figure 98
on page
127.
2
3
4
5
1
7
8
6
COM
1
2
3
4
24V
6
7
8
0V
5
Vista de pagina 125