Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012 153
Drive Comparisons Chapter 1
Table 64 - Recommended Leg Fuses - 690V AC Input Frame D Drives
Figure 107 - Frame C Non-Regenerative Drive - AC Input Line Fuse Location
Frame Drive
Current
Rating Code
DC
Amps
AC Line
Amps
Qty Bussmann Ferraz Shawmut (Gould Shawmut) SIBA
Square Body - DIN 43653 Stud-Mount
D 678 678 553 6 170M6260 + switch 170H0069 V300260 + switch MS 3V 1-5 UR 20 635 32.630 + switch 28 001 04
791 791 645 6 170M6262 + switch 170H0069 X300262 + switch MS 3V 1-5 UR 20 635 32.800 + switch 28 001 04
904 904 738 6 170M6263 + switch 170H0069 Y300263 + switch MS 3V 1-5 UR 20 635 32.900 + switch 28 001 04
1K0 1017 830 6 170M6264 + switch 170H0069 Z300264 + switch MS 3V 1-5 UR 20 635 32.1000 + switch 28 001 04
1K1 1130 922 6 170M6265 + switch 170H0069 A300262 + switch MS 3V 1-5 UR 20 635 32.1100 + switch 28 001 04
1K2 1243 1014 6 170M6266 + switch 170H0069 B300266 + switch MS 3V 1-5 UR 20 635 32.1250 + switch 28 001 04
1K4 1413 1153 6 170M6267 + switch 170H0069 C300267 + switch MS 3V 1-5 UR 20 635 32.1400 + switch 28 001 04
1K5 1582 1291 12 170M6262 + switch 170H0069 X300262 + switch MS 3V 1-5 UR 20 635 32.800 + switch 28 001 04
Note: Drive shown with front covers removed and Control EMI shield lowered.
AC Input fuses and switches are located on the bus bars behind the Control EMI
shield, which holds the Control board.