12 Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012
Chapter 1 Drive Comparisons
Input Power
120V AC ±10% n/a n/a n/a n/a
200…240V AC ±10% 47…63 Hz 48…62 Hz 47…63 Hz 47…63 Hz
380…480V AC ±10% 48…63 Hz 48…62 Hz 48…63 Hz 47…63 Hz
500…600V AC ±10% n/a n/a n/a 47…63 Hz
Single Phase n/a n/a n/a n/a
Three Phase All All All All
Input Inductor 3% required 3% required 3% recommended 3% recommended
Logic Ride-thru – – – 0.5…2.0 s
Power Ride-thru None None None 15 ms at full load
Extended Power Ride-thru No No No No
Transient Protection MOV – – –
Dynamic Braking Optional Optional Optional Optional
Output Power
120V DC n/a n/a n/a n/a
240V DC 1…300 Hp 1.5…300 Hp 1.5…300 Hp 1.5…300 Hp
500V DC 2…600 Hp 3…600 Hp 3…600 Hp 2…900 Hp
600V DC n/a n/a n/a 50…1250 Hp
700V DC n/a n/a n/a 400…1400 Hp
Efficiency (100% Speed & Load) – 99.30% 99.30% –
Power Factor 88% @ max speed 88% @ max speed 88% @ max speed Speed dependent
Output Power Device SCR SCR SCR SCR
Protection
Ground Fault – No No Yes
Ground Warning – No No No
Current Limit Yes Yes Yes Yes
Over Current Yes Yes Yes Yes
Electronic Overload Yes No – –
Overload Meets NEC per UL – No – –
Speed Sensitive Overload – No – –
Enclosure
Open / IP20 Yes Yes Yes Yes
Table 1 - Drive Specification and Feature Comparisons (Continued)
Attributes 1395 1397 FlexPak 3000 PowerFlex DC
Comentarios a estos manuales