Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012 149
Drive Comparisons Chapter 1
Figure 104 - Frame D Field Circuit Fuse Location
Fuses for Regenerative Frame C and D Drives
Leg fuses are internally mounted and provided with frames C and D drives. See
Fuse Code FS4 in Frame C and D Fuse Designations on page 146
. Also, see
Frame C Regenerative Drive - Leg Fuse Location on page 151
and Frame D
Regenerative Drive - Leg Fuse Location on page 151
.
Table 49 - Recommended Leg Fuses - 230V AC Input Frame C Drives
Table 50 - Recommended Leg Fuses - 230V AC Input Frame D Drives
Table 51 - Recommended Leg Fuses - 460V AC Input Frame C Drives
Top, left side of drive control panel.
Frame Drive
Current
Rating Code
DC
Amps
AC
Line
Amps
Qty Bussmann Ferraz Shawmut (Gould Shawmut) SIBA
Square Body - Flush End Contact
C 521 521 426 6 170M5464 + switch 170H0069 6,9 URD 32 TTF 800 + switch MS 3-V1-5 BS 20 671 32.800 + switch 28 001 04
700 700 571 6 170M5464 + switch 170H0069 6,9 URD 32 TTF 800 + switch MS 3V 1-5 BS 20 671 32.800 + switch 28 001 04
Frame Drive
Current
Rating Code
DC
Amps
AC
Line
Amps
Qty Bussmann Ferraz Shawmut (Gould Shawmut) SIBA
Square Body - DIN 43653 Stud-Mount
D 875 875 715 6 170M6263 + switch 170H0069 Y300263 + switch MS 3V 1-5 UR 20 635 32.900 + switch 28 001 04
1K0 1050 858 6 170M6264 + switch 170H0069 Z300264 + switch MS 3V 1-5 UR 20 635 32.1000 + switch 28 001 04
Frame Drive
Current
Rating Code
DC
Amp
s
AC
Line
Amps
Qty Bussmann Ferraz Shawmut (Gould Shawmut) SIBA
Square Body - Flush End Contact
C 495 495 404.4 6 170M5462 + switch 170H0069 6,9 URD 32 TTF 630 + switch MS 3-V1-5 BS 20 671 32.630 + switch 28 001 04
667 667 544.9 6 170M5464 + switch 170H0069 6,9 URD 32 TTF 800 + switch MS 3-V1-5 BS 20 671 32.800 + switch 28 001 04